  4. On line measurement of temperature and water vapor in CH4/air premixed flame usi

On line measurement of temperature and water vapor in CH4/air premixed flame usi

上传者: 2021-02-17 15:46:41上传 PDF文件 447KB 热度 7次
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame. Line-of-sight properties are analyzed, but line-of-sight results are not path average values for temperature measurements. The measurements are performed on a flat burner based on