华为海思NB_IoT 657版本AT指令集
华为海思NB_IoT模组,657版本AT指令集Contact us110第5页共110页1 IntroductionThis document gives details of the AT Command Set supported by the hisiHi2110 chip loaded with v100R100C20B657 and v150R100C10B120 firmwareAt boot the following string will be outputNeul OK After this string has been received the AT Command processor is ready toaccept at commandsIf the Applications core was rebooted or restarted forany reason that wasn't anoormal power-on sequence, a message will be output before theNeul< CR>OK string. See Chapter 7 for more detailsIn case external MCU intervene the process of update, unsolicited informationinforms the external MCU update state Please reference AT document [l] for more detailinformation FIRMWARE DOWNLOADINGIndicates UE is downloadingpdate package FIRMWARE DOWNLOAD FAILED< CR> Indicates download failed FIRMWARE DOWNLOADEDIndicates download finishedFIRMWARE UPDATING Indicates UE is updatingFIRMWARE UPDATE SUCCESSIndicates update success, butnot report update statefirmware package server yet第6页共110页 FIRMWARE UPDATE FAILED Indicates UE update fail FIRMWARE UPDATE OVERIndicatesreportedupdate state to firmwarepackage server.During FOTA procedure, device shouldn' t operate modem until FIRMWARE UPDATEOVER" is reportedE.g. AT+NRB, power off are not permitted otherwise, indescribable error will be made. 11.1 Definitions carriage return character line feed character><>parameter name. Angle brackets do not appear on command line>[J Option parameter Square brackets do not appear on the command line1.2 AT Command SyntaxAT+plp2[p3[…]Sct commandSct commandCheck current sub-parameterSAT+Ecmd>?Read CommandvalucsCheck possiblc sub-paramctcraT+>=?Test CommandvalucsMultiple commands can be placed on a single line using a semi-colon ( I)between commands. Only the first command should have at prefix. Commands can beupper or lower case.第7页共110页When entering at commands spaces are ignored except in the following caseswithin quoted strings, where they are preservede within an unquoted string numeric parametere within an ip addresswithin the aT command name upto and including aor?They can be used to make the input more human readable On input, at least acarriage-return is required. A new-line character is ignored so it is permissible to usecarriage-return line-feed pairs on the inputno command is entered after the at token ok wilk be returned. if an invalidcommand is entered error will be returnedOptional parameters, unless explicitly stated, need to be provided up to the lastparameter being entered1.3 AT Command ResponsesWhen the AT Command processor has finished processing a line it will output eitherOK, ERROR or an error code indicating that it is ready to accept a new commandSolicited informational responses are sent before the final ok or ERROR. Unsolicitedinformation responses will never occur between a solicited informational response andthe final ok or errorFor AT Commands aligned to the 3Gpp 27.007 specification error codes are enabledwith the CMEE command, else the ERROR message will be returned For AT Commandsaligned to the ETSI 127.005 specification, a CMS error will be returned where specifiedCMS error will be returned where specified第8页共110页Responses will be of the format+CMD1: OKOK1.4 3GPP Alignment3GPP commands are aligned to 3GPP TS 27.007 v14.3.0 (2017-03) For clarificationon 3GPP commands, please refer to this document.1.5 Modification HistoryD。 cument IpFirmware ModificationReleaseV100R100C00B350Output how uses before and after each lineIssue 2B350SP13of outputPreviously only the trailing was generatedV100R100C00B350Issue2B350SP13Error behaviour aligned to +Cmee=o has beenimplemented. Only' OK and" ERROR" are returned00R100c00B600B600New commands added: +nband,+nloglevel +CmeeIssue 1have been added100R100c00B6003GPP numeric error codes have been implementedIssueB600Previous text errors have been remove en implementedV100R100C00B650New command +COnFig added behaviour of +COPsB650Issue 1and +cgdcont when autoconnect is enabled hasbeen added100R100C00B650+nUeStaTS extended to return coverage levelIssue 3B650SP1Clarify syntax for some execute commandsV100R100C00B650Issue 4B650SP6 Minor changes to behaviour of some commands第9页共110页100R100c00B650Issue 5B655SP2Minor changes to behaviour of some commands√100R100c00B656Issue 6B656Fix some description error and add fota statusV100R100c00B656B656SP1New command at+nccd addedIssue 7Add rsra for AT+NUESTATS=RADIOV100R100c00B656Issue 8B656SP2 New command AT+ NATSPEED addedV100R100c00B656B656SP2Add maximum value for parameter "timeout"of AT+Issue 9NATSPEEDAligned to ETSI 127.005 v130.0(2016-01) for+CSMS+CNMA, +CsCA,+Cmgs,+Cmgc,+ SoDCP +CRTDCPCommands added: +CGACt, +NCCId CTZR, +CPSMS+CEDRXS, +NRDCtRL, +NRDSET+NRDEXEC, +NRDCTRL,+V100R100C00B657Issue 1B657NRDSET, +NRDEXEC, +NFWURD +NMSTATUS, +NTPERMIDAdd +Ceres n=3.45Add NUESTAtS= cellAdd +NCONFIG: CELL RESELECTION, ENABLE BIPAdd +CGDCONT: NSLPI+CGMR will return information for each coreV100R100C00B657Issue 2B657 Modify some typo errors第10页共110页2. Commands(3GP Aligned to 27.007)2.1 Request Manufacturer Identification (+CGMI)CommandResponseExample+CGMIAT+CGMD+CME ERROR: NeulOK+CGMI=?AT+CGMI=?OKDescriptionThis command returns the manufacturer information. by default this will returnNeul"on the standard platform. Refer to Chapter 6 Error Values for possible valuesDefined values: the total number of characters, including line terminators, in theinformation text shall not exceed 2048 characters. Text shall not contain the sequence0 or oKHisi Hi2110 Implementation2.2 Request Manufacturer Model (+CGMM)CommandResponseExample+CMMmodel>AT+CGMM+CME ERROR: Hi211XOK+CMM=?AT+CGMM=?OKDescriptionThis command returns the manufacturer model information. By default this will第11页共110页return" Hi211X on the standard platform. Refer to Chapter 6: Error Values for possible valuesDefined values: the total number of characters, including line terminators, in theinformation text shall not exceed 2048 charactersText shall not contain the sequence 0or OKHisi Hi2110 Implementation2.3 Request Manufacturer Revision (+CGMR)This command returns the manufacturer revision the text is human readable and isnot intended for microcontroller parsingBy default this will return the firmware revision -release and buildCommandResponseExamplAT+CGMR+CGMRSECURITYV100R100C10B660+CME ERROR:err>PROTOCOL V100R100C10B660APPLICATION V100R100C10B660RADIO, pcb052_v2. 0OK+CGMR=?AT+CGMR=?DescriptionExecution command returns one or more lines of information text . Refer toChapter 6: Error Values for possible valuesDefined values: the total number of characters, including line terminators, in theinformation text shall not exceed 2048 characters第12页共110页
用户评论